  • NEC Requirements for Generators and Standby Power Systems
    Mike Holt Enterprises, Inc • www MikeHolt com • 888 NEC CODE (632 2633) 5 NEC Requirements for Generators and Standby Power Systems 445 18 Disconnecting Means Generators must have one or more disconnecting means that disconnects all power, except where: Figure 445–7 (1) The driving means for the generator can be readily shut down, and
  • Mike holt - Electrician Talk
    TheNEC also requires certain types of circuits in specific places in addition to the minimum requirements based on the VA per sq ft calculation A dwelling unit kitchen, dining room, breakfast room, pantry, or similar area must have at least two 20A, 120V small-appliance receptacle
  • Continuous Load: what is maximum current - Electrician Talk
    From the 2023 NEC Article 100 Definition: Continuous Load: A load where the maximum current is expected to continue for 3 hours or more 210 20(A) Continuous and Noncontinuous Loads "Where a branch circuit supplies continuous loads or any combination of continuous and noncontinuous loads
  • EMT Fittings for Damp Locations. | Electrician Talk
    NEC 358 42 Couplings and Connectors Couplings and connectors used with EMT shall be made up tight Where buried in masonry or concrete, they shall be concretetight type Where installed in wet locations, they shall comply with 314 15 No mention of "damp"
  • INTRODUCTION TO UNIT 5—RACEWAY AND BOX CALCULATIONS - Electrician Talk
    of the NEC are the primary references for determining allowable con-ductor fill in raceways For the most common condition, where multi-ple conductors of the same size are installed together in a raceway, the maximum number of conductors permitted can be determined from the tables in Annex C For situations where conductors of different
  • 110. 15 High-Leg Marking - Electrician Talk
    Reading the NEC for this is nit picking I have worked with 100's of POCO's, I bet IF you can get a wild leg service they make up the rules NOT at all caring for what the NEC says Argue with the entity providing you power is a fools errand You do what they say, use the colors they say and be happy
  • 80% rule? - Electrician Talk
    80% rule applies to continious loads such as motors, lighting or any load expected to be on 3 hours or more A breaker is rated for 100% of the noncontinious load which may include outlets or other small appliance
  • What is PVC support spacing in the NEC? | Electrician Talk
    Easy but you have to pay a little attention to material and labor costs Once you get above 1" trade size generally speaking supports are starting to get to be substantial so supports drive costs more than conduit
  • Usage of flexible cords. - Electrician Talk
    How do you guys interpret the interaction between 400 10 and 400 12 in the nec? If you are connecting a cord and plug machine in a shop, which arguably creates noise and vibration, are you allowed to disregard 400 12 which states you cannot have cord run through a drop ceiling? I know I wouldn't do it myself, but this section of code is very vague
  • Understanding Table 220-55 - Electrician Talk
    The NEC does not define ranges, ovens or cooktops but based on manufacturers usage a range is a unit that has a cooktop and oven built together in one appliance An oven is just a single or double appliance for baking , roasting, etc A cooktop is just the burners without the oven